Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 09460mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-27 17:45:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-27 17:15:02 17:15:02 Initialize Modem [15220mV] 17:15:09 +KSUP: 0 17:15:10 +CEREG: 2 17:15:10 +CEREG: 0 17:15:10 +CEREG: 2 17:15:11 +CEREG: 5,"8010","08DAE50C",7 17:15:11 Matched '+CEREG: 5,*' 17:15:12 AT+KPATTERN="SOLAR" 17:15:12 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 17:15:12 Charge Status = 0 [CHARGE_STATUS_OFF] 17:15:12 Battery Voltage = 10446mV 17:15:12 Input Voltage = 15179mV 17:15:12 Output Voltage = 15202mV 17:15:12 Battery Current = -1mA 17:15:12 Input Current = 76mA 17:15:12 Die Temp = 625 x10 DegC 17:15:12 Thermistor Voltage = 5366 17:15:13 BSR = 0mOhm 17:15:13 OK 17:15:13 Matched 'OK' 17:15:13 AT+COPS? 17:15:13 +COPS: 0,0,"Hologram",7 17:15:13 OK 17:15:13 Matched 'OK' 17:15:13 AT+CESQ 17:15:13 +CESQ: 99,99,255,255,16,50 17:15:13 OK 17:15:13 Matched 'OK' 17:15:13 AT+KBND? 17:15:14 +KBND: 0,00000000000008000000 17:15:14 OK 17:15:14 Matched 'OK' 17:15:14 Connect [14587mV] 17:15:14 AT+CCLK? 17:15:14 +CCLK: "19/10/27,17:15:08+42" 17:15:14 OK 17:15:14 Matched 'OK' 17:15:14 ATS0=0 17:15:14 OK 17:15:14 Matched 'OK' 17:15:15 ATD*99***1# 17:15:15 CONNECT 17:15:15 Matched 'CONNECT*' 17:15:15 Connected [14692mV] 17:15:15 001 Initializing Interface: [Connect Init] 17:15:15 Initialise TCP/IP Stack 17:15:15 001 Initializing Interface: [Start PPP] 17:15:15 Connecting 17:15:18 001 Initializing Interface: [PPP Connected] 17:15:18 Connected 10.170.119.223 17:15:18 002 Initializing FTP: [Resolve Server] 17:15:18 DNS Lookup ftp.enviroscanplus.com 17:15:19 002 Initializing FTP: [Connect Server] 17:15:19 Open Connection to ftp.enviroscanplus.com 17:15:21 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 17:15:22 331 User modemtesting@enviroscanplus.com OK. Password required 17:15:23 230 OK. Current restricted directory is / 17:15:24 002 Initializing FTP: [CWD] 17:15:24 250 OK. Current directory is /HL7800 17:15:25 002 Initializing FTP: [SET Binary Mode] 17:15:25 200 TYPE is now 8-bit binary 17:15:25 003 Transferring 17:15:26 004 Uploading to Server 17:15:27 004 Uploading to Server: [Upload File] 17:15:27 227 Entering Passive Mode (198,38,77,48,202,216) 17:15:30 001 Initializing Interface 17:15:44 Disconnect 17:15:48 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&ŒàèÇ}'}"}(}"}=¦~~ÿ}#À!}%}#} }0User requesty{~ 17:15:48 NO CARRIER 17:15:48 Matched 'NO CARRIER' 17:15:48 AT+CESQ 17:15:48 +CESQ: 99,99,255,255,16,50 17:15:48 OK 17:15:48 Matched 'OK' 17:15:48 AT+CPWROFF 17:15:48 +CEREG: 0 17:15:48 +CEREG: 0 17:15:48 OK 17:15:48 Matched 'OK' 17:15:57 Error timeout 17:15:57 Power down [14492mV]