Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 13348mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-03 21:15:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-03 20:45:02 20:45:02 Initialize Modem [13619mV] 20:45:10 +CEREG: 2 20:45:11 +CEREG: 0 20:45:11 +CEREG: 2 20:45:11 +KSUP: 0 20:45:13 +CEREG: 5,"8010","08DAE50C",7 20:45:13 Matched '+CEREG: 5,*' 20:45:14 AT+KPATTERN="SOLAR" 20:45:15 Charger State = 0800 [CHARGER_STATE_CC_CV_CHARGE] 20:45:15 Charge Status = 00d [CHARGE_STATUS_VIN_UVCL_ACTIVE] 20:45:15 Charge State Alerts = 0000 20:45:15 Charge Status Alerts = 00 20:45:15 System Status Alerts = 067 20:45:15 Unloaded Charger State = 2048 [CHARGER_STATE_CC_CV_CHARGE] 20:45:15 Unloaded Charge Status = 0 [CHARGE_STATUS_VIN_UVCL_ACTIVE] 20:45:15 Unloaded Battery Voltage = 10270mV 20:45:15 Unloaded Input Voltage = 14014mV 20:45:15 Unloaded Output Voltage = 14040mV 20:45:16 Unloaded Battery Current = -1mA 20:45:16 Unloaded Input Current = 22mA 20:45:16 BSR = 0mOhm 20:45:16 TC ChargeTimer = 156 20:45:16 TC VTimer = 163 20:45:16 Battery Voltage = 10266mV 20:45:16 Input Voltage = 13985mV 20:45:16 Output Voltage = 14000mV 20:45:16 Battery Current = 1mA 20:45:16 Input Current = 65mA 20:45:16 Die Temp = 304 x10 DegC 20:45:17 Thermistor Voltage = 10659 20:45:17 nRF Die Temp = 220 x10 DegC 20:45:17 OK 20:45:17 Matched 'OK' 20:45:17 AT+COPS? 20:45:17 +COPS: 0,0,"Hologram",7 20:45:17 OK 20:45:17 Matched 'OK' 20:45:17 AT+CESQ 20:45:17 +CESQ: 99,99,255,255,17,48 20:45:17 OK 20:45:17 Matched 'OK' 20:45:18 AT+KBND? 20:45:18 +KBND: 0,00000000000008000000 20:45:18 OK 20:45:18 Matched 'OK' 20:45:18 Connect [13534mV] 20:45:18 AT+CCLK? 20:45:18 +CCLK: "19/11/03,20:45:19+42" 20:45:18 OK 20:45:18 Matched 'OK' 20:45:18 ATS0=0 20:45:19 OK 20:45:19 Matched 'OK' 20:45:19 ATD*99***1# 20:45:19 CONNECT 20:45:19 Matched 'CONNECT*' 20:45:19 Connected [13579mV] 20:45:19 001 Initializing Interface: [Connect Init] 20:45:19 Initialise TCP/IP Stack 20:45:19 001 Initializing Interface: [Start PPP] 20:45:19 Connecting 20:45:22 001 Initializing Interface: [PPP Connected] 20:45:22 Connected 10.170.119.223 20:45:23 002 Initializing FTP: [Resolve Server] 20:45:23 DNS Lookup ftp.enviroscanplus.com 20:45:24 002 Initializing FTP: [Connect Server] 20:45:24 Open Connection to ftp.enviroscanplus.com 20:45:25 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 20:45:26 331 User modemtesting@enviroscanplus.com OK. Password required 20:45:27 230 OK. Current restricted directory is / 20:45:28 002 Initializing FTP: [CWD] 20:45:28 250 OK. Current directory is /HL7800 20:45:29 002 Initializing FTP: [SET Binary Mode] 20:45:29 200 TYPE is now 8-bit binary 20:45:29 003 Transferring 20:45:30 004 Uploading to Server 20:45:31 004 Uploading to Server: [Upload File] 20:45:31 227 Entering Passive Mode (198,38,77,48,199,208) 20:45:35 003 Transferring 20:45:35 004 Uploading to Server 20:45:36 227 Entering Passive Mode (198,38,77,48,198,238) 20:45:39 001 Initializing Interface 20:45:46 Disconnect 20:45:50 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&55bf}'}"}(}")å~~ÿ}#À!}%}#} }0User requesty{~ 20:45:50 NO CARRIER 20:45:50 Matched 'NO CARRIER' 20:45:50 AT+CESQ 20:45:50 +CESQ: 99,99,255,255,16,49 20:45:50 OK 20:45:50 Matched 'OK' 20:45:50 AT+CPWROFF 20:45:50 +CEREG: 0 20:45:51 +CEREG: 0 20:45:51 OK 20:45:51 Matched 'OK' 20:46:00 Error timeout 20:46:00 Power down [13585mV]