Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14269mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-04 05:45:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-04 05:15:02 05:15:02 Initialize Modem [14251mV] 05:15:10 +CEREG: 2 05:15:10 +KSUP: 0 05:15:10 +CEREG: 0 05:15:10 +CEREG: 2 05:15:11 +CEREG: 5,"8010","08DAE50C",7 05:15:11 Matched '+CEREG: 5,*' 05:15:12 AT+KPATTERN="SOLAR" 05:15:13 Charger State = 0040 [CHARGER_STATE_CC_CV_CHARGE] 05:15:13 Charge Status = 04d [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 05:15:13 Charge State Alerts = 0000 05:15:13 Charge Status Alerts = 00 05:15:13 System Status Alerts = 147 05:15:13 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 05:15:13 Unloaded Charge Status = 4 [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 05:15:13 Unloaded Battery Voltage = 11725mV 05:15:13 Unloaded Input Voltage = 14657mV 05:15:13 Unloaded Output Voltage = 14681mV 05:15:14 Unloaded Battery Current = 196mA 05:15:14 Unloaded Input Current = 190mA 05:15:14 BSR = 0mOhm 05:15:14 TC ChargeTimer = 0 05:15:14 TC VTimer = 0 05:15:14 Battery Voltage = 11703mV 05:15:14 Input Voltage = 14657mV 05:15:14 Output Voltage = 14680mV 05:15:14 Battery Current = 130mA 05:15:14 Input Current = 190mA 05:15:15 Die Temp = 358 x10 DegC 05:15:15 Thermistor Voltage = 10378 05:15:15 nRF Die Temp = 212 x10 DegC 05:15:15 OK 05:15:15 Matched 'OK' 05:15:15 AT+COPS? 05:15:15 +COPS: 0,0,"Hologram",7 05:15:15 OK 05:15:15 Matched 'OK' 05:15:15 AT+CESQ 05:15:15 +CESQ: 99,99,255,255,21,50 05:15:15 OK 05:15:15 Matched 'OK' 05:15:16 AT+KBND? 05:15:16 +KBND: 0,00000000000008000000 05:15:16 OK 05:15:16 Matched 'OK' 05:15:16 Connect [14231mV] 05:15:16 AT+CCLK? 05:15:16 +CCLK: "19/11/04,05:15:15+42" 05:15:16 OK 05:15:16 Matched 'OK' 05:15:17 ATS0=0 05:15:17 OK 05:15:17 Matched 'OK' 05:15:17 ATD*99***1# 05:15:17 CONNECT 05:15:17 Matched 'CONNECT*' 05:15:17 Connected [14283mV] 05:15:17 001 Initializing Interface: [Connect Init] 05:15:17 Initialise TCP/IP Stack 05:15:17 001 Initializing Interface: [Start PPP] 05:15:17 Connecting 05:15:20 001 Initializing Interface: [PPP Connected] 05:15:20 Connected 10.170.119.223 05:15:21 002 Initializing FTP: [Resolve Server] 05:15:21 DNS Lookup ftp.enviroscanplus.com 05:15:21 002 Initializing FTP: [Connect Server] 05:15:21 Open Connection to ftp.enviroscanplus.com 05:15:23 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 05:15:24 331 User modemtesting@enviroscanplus.com OK. Password required 05:15:25 230 OK. Current restricted directory is / 05:15:26 002 Initializing FTP: [CWD] 05:15:26 250 OK. Current directory is /HL7800 05:15:27 002 Initializing FTP: [SET Binary Mode] 05:15:27 200 TYPE is now 8-bit binary 05:15:27 003 Transferring 05:15:27 004 Uploading to Server 05:15:28 004 Uploading to Server: [Upload File] 05:15:28 227 Entering Passive Mode (198,38,77,48,196,174) 05:15:32 001 Initializing Interface 05:15:44 Disconnect 05:15:48 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&}=ý¨}!}'}"}(}"€^~~ÿ}#À!}%}#} }0User requesty{~ 05:15:48 NO CARRIER 05:15:48 Matched 'NO CARRIER' 05:15:48 AT+CESQ 05:15:48 +CESQ: 99,99,255,255,22,49 05:15:48 OK 05:15:48 Matched 'OK' 05:15:48 AT+CPWROFF 05:15:48 +CEREG: 0 05:15:48 +CEREG: 0 05:15:48 OK 05:15:48 Matched 'OK' 05:15:57 Error timeout 05:15:57 Power down [14233mV]